Parts
Replacement parts for any cooling tower: any manufacturer, any model, any age. If you have your own crews and only need the components, this is the right page.
We supply parts for towers nobody else will
A large proportion of the industrial cooling towers running on the Gulf Coast were built by companies that have been sold, renamed, absorbed or shut down. The tower is fine. The support behind it is gone.
When that happens, an owner is normally told the tower is obsolete and offered a replacement. Very often that is not true. The component that failed is a gearbox, a fan, a driveline, a nozzle or a fill pack, and all of those are available, just not from the name on the casing.
Because we are independent and have been doing this since 1964, we can identify what is fitted, find the current equivalent, and confirm it fits before you buy it. Names like Lillie-Hoffman, Ecodyne, Thermal Dynamic and the old Pritchard line are routine to us, and so are the discontinued component lines behind them: Robertshaw vibration switches, Reliance Electric motors, wood lath fill.
What that means in practice
- Any manufacturer, any model: including towers whose original makers no longer exist
- Cross-referencing from an obsolete part to a current, verified equivalent
- Identification from photographs when the nameplate is gone or unreadable
- Independent recommendation: we do not manufacture towers, so we have nothing to protect
- Or we fit it too: see repairs and upgrades

A nameplate is the fastest route to a correct part. Photograph it before you call.
Very common on older towers. Photographs of the component in place, with a tape measure for scale, are usually enough for us to identify it.
Mechanical
The drive train: motor, drive shaft, gear reducer, fan, plus the vibration switch that protects all of it. Highest value, longest lead times, and the components whose failure takes the cell out immediately.
Gear reducers
Right-angle fan drives, including direct replacements for the Marley Geareducer line. Frequently rebuilt in place.
View componentFans
Fiberglass and aluminum fan assemblies, blades and hubs: Hudson, Amarillo Chittom, Moore and Cofimco.
View componentDrive shafts & couplings
Composite and steel drive shafts with flexible disc couplings: Addax, Amarillo, Rexnord Thomas and TB Wood's.
View componentMotors
Cooling tower duty fan motors: severe duty and premium efficiency, single and two-speed, any horsepower.
View componentVibration switches
Mechanical and electronic vibration cut-outs: Murphy VS2, PMC/BETA and Metrix. The cheapest protection a fan drive can have.
View componentInternal
Everything the water and air touch inside the tower. This is where thermal performance is won and lost, and where most towers are quietly losing capacity right now.
Fill
Film and splash fill for counterflow and crossflow towers, including fouling-resistant grades: Brentwood and C.E. Shepherd.
View componentDrift eliminators
Cellular and blade drift eliminators to control drift loss, plume and deposition: Brentwood CDX and C.E. Shepherd DRU.
View componentNozzles
Gravity-flow basin nozzles and pressurized spray nozzles for crossflow and counterflow distribution: Fisher, Dek-Spray and C.E. Shepherd.
View componentDistribution systems
Counterflow header and lateral systems and crossflow distribution basins, including redesign to correct uneven water loading.
View componentExternal
Structure, enclosure, access and control. Less glamorous than the mechanical train and responsible for most of what an inspection actually writes up.
Fan stacks
FRP fan cylinders and velocity-recovery stacks in Class I, II and III fire ratings: Midwest, Polymer Fabrication and BAC · Baltimore Aircoil.
View componentCasing & louvers
FRP casing in 4.2 corrugated and 5.33 V-Beam profiles, and inlet louvers. Fire rated panels available with UL flame spread of 25 or less.
View componentLumber & hardware
CTI-grade treated Douglas fir and redwood, plywood, and fasteners in 304/316 stainless, silicon bronze, monel and hot-dip galvanized.
View componentFRP shapes
Pultruded fiberglass angle, channel, tube, decking, grating and walkway sections for structural and safe-access work.
View componentValves
Butterfly valves in the Bray 30 and 31 series, crossflow flow control valves, and bottom-dump valves from 18 to 60 inches.
View componentEverything else a cooling tower needs
These do not warrant a page each, but we supply them. If it belongs on a cooling tower and it is not listed anywhere on this site, ask anyway; the list above is the common stuff, not the limit.
- Basin liners & covers
- Belts & sheaves
- Isolation springs
- Ladders & cages
- Stairways & landings
- Handrails & kneerails
- Walkways & grating
- Pipe & pipe fittings
- Pumps
- Sealants & coatings
- Air seals & partitions
- Access doors & view ports
- Fasteners & connection hardware
- Fill supports & hangers
Temporary cooling capacity while a tower is rebuilt or repaired has historically been part of what we arrange. If you need bridging capacity for an outage, ask us early; it is a lead-time item, and in storm season it is a scarce one.
What we need from you
The more of this you have, the faster and more accurate the quote. If you only have some of it, send what you have.
The tower
- Manufacturer and model, if known
- Number of cells
- Crossflow or counterflow
- Induced or forced draft
- Structural material
The component
- Photograph of the nameplate
- Photograph in place, with scale
- Key dimensions if you have them
- Quantity needed
- What failed, and how
The situation
- Is the cell in service or down?
- When do you need it?
- Is it tied to an outage window?
- Do you need installation as well?
- Delivery address and site access
Not sure what you are looking at?
That is a normal call for us. Photograph the component and the nameplate, send them over, and we will identify it and tell you what the current equivalent is.
- Phone
- (713) 643-0691
- Shop & office
-
3811 Cedar Blvd Ste A
Baytown, TX 77523